Signed Contract_W. Third Reservoir, IIW EngineersDATE: July 30, 2009 The purpose of this memorandum is to request your authorization and approval with our recommendation to award IIW Engineers the Inspection and Design Engineering Services contract for the West Third Reservoir. This contract is for the Professional Engineering Inspection and Design Services to provide Interior & Exterior Inspection Report(s) with Corrective Action Plan(s) of the West Third Street Reservoir and Control Valve Housing Building & Pit. The West Third Street Reservoir is a below ground, circular concrete tank constructed in 1914. The concrete roof was added in 1921. The reservoir is 180 feet in diameter and 41 feet deep. The reservoir holds approximately 7,500,000 gallons. This reservoir has not been professionally inspected since 1988. Completion of this project will provide the inspection reports and plans for corrective actions that warrant repair, servicing or replacement, or any issues believed to constitute conditions that warrant continued observation for potential future repair, servicing or replacement. The Inspection Report shall include descriptions of the locations of any relevant observed problem, any faults in the structure and include recommendations, prioritizations and cost estimates for the maintenance, repair, service and/or replacements. The final Inspection Report shall be submitted no later than October 1, 2009. The RFP was posted on the City's website and I personally called eight (8) engineering firms to inform them of this posting. We received five (5) Proposal Acknowledgements, with four (4) firms indicating that they were interested in sending a Bid Proposal. On July 27, 2009, we received two (2) Bid Proposals. The firms that submitted proposals are as follows: COMPANY LOCATION BID AMOUNT 1. IIW Engineers & Surveyors, P.C. Dubuque, IA $17,655 2. Pro-Dive Ottawa, IL $45,171 In review of the two proposals received, IIW Engineering was found to be the lowest responsible bidder in the amount of $17,655. Their bid amount is approximately 3.5% below the amount budgeted for this project. I have attached a copy of the RFP, the Bid Proposal and the supporting documents submitted by IIW Engineers & Surveyors, P.C. for your review. As a result of the type of services requested and its cost, City Council Action/Authorization is not required. ACTION: Staff and I are requesting your authorization and approval to proceed with this project in awarding it to the lowest responsible bidder, IIW Engineering of Dubuque, Iowa in the amount of $17,655. Monies for this project were budgeted in our FY2009 CIP 740- 1412, fund balance $18,302. Staff and I are available to meet with you at your convenience to discuss and answer any questions you may have. - - -- BG:ve Attachments cc: Jacqueline Vanek, Water Plant Manager File FROM: Jacqueline Vanek, Water Plant Manager SUBJECT: Award Inspection and Engineering Services Contract for the West Third Reservoir to IIW Engineers and Surveyors, P.C. of Dubuque, Iowa in the amount of $17,655 CIP #740-1412, Fund Balance - $18,302 DATE: July 29, 2009 The purpose of this memorandum is to recommend awarding IIW Engineers the Inspection and Design Engineering Services contract for the West Third Reservoir. This contract is for the Professional Engineering Inspection and Design Services to provide Interior & Exterior Inspection Report(s) with Corrective Action Plan(s) of the West Third Street Reservoir and Control Valve Housing Building & Pit. The West Third Street Reservoir is a below ground, circular concrete tank constructed in 1914. The concrete roof was added in 1921. The reservoir is 180 feet in diameter and 41 feet deep. The reservoir holds approximately 7,500,000 gallons. This reservoir has not been professionally inspected since 1988. Completion of this project will provide the inspection reports and plans for corrective actions that warrant repair, servicing or replacement, or any issues believed to constitute conditions that warrant continued observation for potential future repair, servicing or replacement. The Inspection Report shall include descriptions of the locations of any relevant observed problem, any faults in the structure and include recommendations, prioritizations and cost estimates for the maintenance, repair, service and/or replacements. The final Inspection Report shall be submitted no later than October 1, 2009. The RFP was posted on the City's website and I personally called eight (8) engineering firms to inform them of this posting. We received five (5) Proposal Acknowledgements, with four (4) firms indicating that they were interested in sending a Bid Proposal. On July 27, 2009, we received two (2) Bid Proposals. The firms that submitted proposals are as follows: COMPANY LOCATION BID AMOUNT 1. IIW Engineers & Surveyors, P.C. Dubuque, IA $17,655 2: Pro-Dive Ottawa, IL $45,171 It is with recommendation of staff that I request to award this project to the lowest bidder, IIW Engineers & Surveyors, P.C. of Dubuque, Iowa, in the amount of $17,655. I have attached a copy of the RFP, the Bid Proposal and the supporting documents submitted by IIW Engineers & Surveyors, P.C. for your review. JV Attachments ~\ 1 \ ~ ~ 1 U I , , ~ ~i \'~ ~~ ~ 111~~~ @9 ¢mu ~9~~Ytl 1.0 Introduction .................................................................. 4 a.0 Project Description ............................................. ............ 4 3.0 Project Scope of Services ................................................ 4 - 5 ~.0 Submission Requirements ............................................... 6 5.0 Proposal Submittal Information ........................................ 7 6.0 Bid Form ...................................................................... 8 Appendix ~ Insurance Requirements Appendix B Project Related Data 10 18 -3- A. iVlinimum items inspected will include: (not inclusive) Roof structure ~ condition Vents Sediment depth (& removal if necessary) Safety considerations Capacity level & head range Fill (Inlet) /Discharge (outlet) pipe Drains Floor structure Leak detection Interior floor & wall coating Overflow weir ~ pipe Support column Safety devices Screens on vents ~ overflows Wall structure Ladders, platforms and handrails ~. Inspection report and plans: The Engineering Consultant will provide the owner with written reports/plans following the completion of the inspection. This report shall contain a narrative, video, photographic documentation, and plans for corrective actions that warrant repair, servicing or replacement by the owner, or any issues believed to constitute conditions that warrant continued observation by the owner for potential. future- repair, servicing or replacement. The Inspection Report shall include descriptions of the locations of any relevant observed problem, any faults in the structure and include recommendations, prioritizations and cost estimates for the maintenance, repair, service and/or replacements. The final Inspection Report shall be submitted to the owner no later than October 1, 2009. C. Reservoir UVater Circulation: The existing inlet/outlet pipes and pumps are configured to fill and empty from the same location. There is insufficient water turnover in the reservoir. The Engineering Consultant shall provide alternatives and costs for reconfiguring the present pump and valve system. The Engineering Consultant shall also provide alternatives and costs for most cost-effective and sustainable method to circulate water within the reservoir. ®. iVleans of Inspection: The Engineering Consultant shall provide interior inspection by means of `an underwater diver equipped with two-way communication devices. The diver shall record the inspection with a video camera and provide the owner with the recorded footage. If necessary for proper inspection of the reservoir floor, sediment shall be removed (vacuumed). Aite~e2ate ~: Reenoteiy pee°ated (Jnde~uvate~ Vehicie (®~, The Engineering Consultant shall provide interior inspection by means of a remotely operated underwater vehicle. The inspection shall be recorded with a video camera. The Inspector shall provide the owner with the recorded footage. -5- If necessary for proper inspection of the reservoir floor, sediment shall be removed (vacuumed). Note #9: Dive technicians and in-tank equipment shall be fully disinfected in accordance with AWWA standard C652-02. All system entries shall be conducted in accordance with applicable OSHA regulations pertaining to Diving and Confined Space entry. Note #2: Complete copy of the 1988 inspection report (74 pages) is available upon request. 4.0 ~UfiIilSSI®N ~~~UI~~~i~N`~~ Before submitting a proposal, each Proposer shall make all investigations and examinations necessary to ascertain site conditions and requirements affecting the full performance of the contract and to verify any representations made_ by the -City upon which the Proposer will rely. -6- PR®~AL SIJIViITT'AL IMF TIN ® Submittal Deadline: July 27, 2009 on or before 2:00 p.m. CST ® Submittal Mailing Address: City of Dubuque Water Department C/O Jacqueline Vanek 1902 Hawthorne Street Dubuque, Iowa 52001 ® Submittal Copies: Two (2) hardcopies and one electronic (pdf) copy of the proposal shall be provided. Submit one (1) original signed proposal and one (1) copy all labeled INTERIOR & EXTERIOR INSPECTION REPORT OF: WEST THIRD STREET RESERVOIR. Submitted proposals must be delivered in printed format. In addition, supply one (1) electronic version of the proposal in Adobe Acrobat format. No faxed or a-mail proposals will be accepted. The original proposal document shall be signed in blue ink by an officer of the company who is authorized to legally bind the Proposer to its provisions. Proposals are to contain a statement indicating the period during which the proposal will remain valid. A period of not less than sixty (60) calendar days from the proposal closing date is required. Each engineering firm assumes full responsibility for delivery and deposit of the completed proposal package on or before the deadline. Any proposals received after the submittal deadline will not be considered, and will be returned unopened to the Proposer. The City of Dubuque will not be responsible for any loss or delay with respect to delivery of the proposals. The City reserves the right to reject any and all bids or to waive any technical ties and irregularities. By virtue of statutory authority, a preference will be given to products and provisions grown and coal produced within the State of Iowa and to Iowa Domestic Labor. The City of Dubuque is not liable for any cost incurred by any Engineering firm prior to the execution of an agreement or contract. Nor shall the City of Dubuque be liable for any costs incurred by the firms in responding to this RFP and those not specified in any contract. All results from this project will remain the property of the City of Dubuque. The engineering firm must provide Proof of Insurance, which complies with the City of Dubuque's Insurance Schedule C (attached). The certificate must be issued to the City before the start of the project and insurance shall be maintained throughout the duration of the contract. Thank you for your consideration and interest in the project. Sincerely, Jacqueline Vanek Water Treatment Plant Manager City of Dubuque -7- INSURANCE SCHE®ULE A 10 INSURANCE REQUIREMENTS F®R PR®FESSI®NAL SERVICES T® THE CITY ®F ®UBUQUE 1. All policies of insurance required hereunder shall be with an insurer authorized to do business in Iowa. All insurers shall have a rating of A or better in the current A.M. Best Rating Guide. 2. All policies of insurance shall be endorsed to provide a thirty (30) day advance notice of cancellation to the City of Dubuque, except for 10 day notice for non- payment, if cancellation is prior to the expiration date. This endorsement supersedes the standard cancellation statement on the Certificate of Insurance. 3. shall furnish a signed Certificate of Insurance to the City of Dubuque, Iowa for the coverage required in Paragraph 6 below. Such Certificates shall include copies of the following endorsements: a) Commercial General Liability policy is primary and non-contributing. b) Commercial General Liability additional insured endorsement. c) Governmental Immunities Endorsement. shall also be required to provide Certificates of Insurance of all subcontractors and all sub-sub contractors who perform work or services pursuant to the provisions of this contract. Said certificates shall meet the same insurance requirements as required of 4. Each certificate shall be submitted to the contracting department of the City of Dubuque. 5. Failure to provide minimum coverage shall not be deemed a waiver of these requirements by the City of Dubuque. Failure to obtain or maintain the required insurance shall be considered a material breach of this agreement. 6. Contractor shall be required to carry the following minimum coverage/limits or greater if required by law or other legal agreement: a) C®MMERCIAL GENE L LIABILITY General Aggregate Limit $2,000,000 Products-Completed Operations Aggregate Limit $1,000,000 Personal and Advertising Injury Limit $1,000,000 Each Occurrence Limit $1,000,000 Fire Damage limit (any one occurrence) $ 50,000 Medical Payments $ 5,000 11 INSU NCE SCHE®ULE A (Continued) INSURANCE REQUIREi~EiVl'S F®R PR®FESSI®NAL SERVICES T® THE CITY ®F ®UBUQUE This coverage shall be written on an occurrence form, not claims made form. All deviations or exclusions from the standard ISO commercial general liability form CG 0001 or Business owners BP 0002 shall be clearly identified. Form CG 25 04 03 97 `Designated Location (s) General Aggregate Limit' shall be included. Governmental Immunity endorsement identical or equivalent to form attached. Additional Insured Requirement: The City of Dubuque, including all its elected and appointed officials, all its employees and volunteers, all its boards, commissions and/or authorities and their board members, employees and volunteers shall be named as an additional insured on General Liability including-"ongoing operations" coverage equivalent to ISO CG 20 10 07 04. b) Automobile $1,000,000 combined single limif c) W®RKERS C®i~iPENSATI®N ~ EIUIPL®YERS LIABILITY Statutory for Coverage A Employers Liability: Each Accident $ 100,000 Each Employee Disease $ 100,000 Policy Limit Disease $ 500,000 d) PR®FESSI®NAL LIABILITY $1,000,000 e) UMERELLA/EXCESS LIABILITY iV0(VE ~n~UP~nC~ ~ub~ai~$al C®ml~~~~A®rt Checklv~~ ^ Certificate of Liability Insurance (2 pages) ^ Designated Location(s) General Aggregate Limit CG 25 04 03 97 ^ Additional Insured CG 20 10 07 04 ^ Governmental Immunities Endorsement ~6CURI~rN CER°fIFIC,4T' F LIB, ILIT'l( I IJRNC i2~"~2o s .PRODUCER (563) 556-0272 FAX: (563j 556-4425 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE Friedman Insurance, Inc. HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR 880 Locust Street - Suite 200 ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. P O Box 759 Dubuque IA 52004-0759 INSURERS AFFORDING COVERAGE NAIC # INSURED INSURERA:S2CUra Insurance Com an 22543 I IW Engineers and Surveyors , P . C . INSURER B: CNA 4155 Pennsylvania Ave INSURER C: INSURER D: Dubuque IA 52002 INSURER E: COVERA S THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, REQUIREMENT , THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. A RE ATE LIM T 0 MAY HAVE EEN D ED B P D AIM . INSR LTR ADD'L IN RD TYPE OF INSURANCE POLICY NUMBER POLICY EFFECTIVE DATE MM/DD/YY POLICY EXPIRATION DATE MM/DD/YY LIMITS GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL LIABILITY PREMISESa ocaErrOence $ 100 , 000 A X CLAIMS MADE OCCUR CP3033699 11/7/2008 11/7/2009 MEDEXP An one erson $ 10,000 PERSONAL&ADVINJURY $ 1,000,000 GENERALAGGREGATE $ 2, 000 , 000 GEN'LAGGREGATELIMITAPPLIESPER: PRODUCTS-COMP/OPAGG $ 2,000,000 POLICY X JE ~ LOC - --- AU TOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1,000,000 X ANYAUTO (Ea accident) A ALLOV4NEDAUT05 A3033700 11/7/2008 11/7/2009 BODILY INJURY SCHEDUL®AUTOS (Per person) $ HIRED AUTOS BODILY INJURY $ NON-0VM1ED AUTOS (Per accident) PROPERTY DAMAGE $ (Per accident) GARAGE LIABILITY AUTO ONLY-EA ACCIDENT $ ANY AUTO OTHER THAN EA ACC $ AUTO ONLY: AGG $ EXCESSlUMBRELLA LIABILITY EACH OCCURRENCE $ 5, 000, 000 X OCCUR ~ CLAIMS MADE AGGREGATE $ 5, 000, 000 $ A DEDUCTIBLE cu3o33702 11/7/2008 11/7/2009 $ X RETENTION $5,000 $ A WORKERS COMPENSATION AND X VJCYTATU- OER EMPLOYERS' LIABILITY E.L. EACH ACCIDENT $ 500 , 000 ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICERIMEMBEREXCLUDED? WC3033701 11/7/2008 11/7/2009 E.L. DISEASE-EA EMPLOYE $ 500,000 If yes, describe under SPECIAL PROVISIONS below E.L. DISEASE -POLICY LIMIT $ 500 , 000 OTHER professional AEA009316390 2/18/2009 2/18/2010 Per ciaim $1,000,000 B Liability Aggregate $1,000,000 DESCRIPTION OFOPERATIONS/LOCATIONSNEHICLESlEXCLUSIONS ADDED BY ENDORSEMENT/SPECIAL PROVISIONS The City of Dubuque, including all its elected and appointed officials, all its employees and volunteers, all its boards, commissions and/or authorities and their board members, employees and volunteers are included as Additional Insureds on the above Liability (Form CG2026 or equivalent). Governmental Immunities Endorsement applies. Waiver of Subrogation applicable to Workers Compensation. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE CITY OF DUBUQUE EXPIRATION DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL 50 W . 13TH STREET 3O DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT CITY HALL FAILURE TO DO SO SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE DUBUQUE, IA 52001 INSURER, ITS AGENTS OR REPRESENTATIVES. AUTHORIZED REPRESENTATIVE Terrance Friedman/TJ T '"~ ACORD 25 (2001/08) ©ACORD CORPORATION 1988 rticnoa ,~,no~ moo. aa„o ~ „r ~ IMP®R1',4N1" If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). DISCLAIMER The Certificate of Insurance on the reverse side of this form does not constitute a contract between the issuing insurer(s), authorized representative or producer, and the certificate holder, nor does it affirmatively or negatively amend, extend or alter the coverage afforded by the policies listed thereon. Al+l~l7 fi n -~vv~~v `.v ~bvV ~IVV~ i NS025 ~o~os~.osa Page 2 of 2 ~ ~ SUBMIT PROPOSAUOFFER PRIOR TO: ~~®S9NG ®ATE: July 27, 2009 CL®StlatC TIME: .2:00 P.M. (local t®~,®~ ISSUE DATE: July 10, 2009 COF1T'ACT: Jacqueline Vanek PI-tOI~E NO: 563-589-4291 FAX NO: 563-589-4297 EMAtL: jvanek@cityofdubuque.org SUBMIT TO: SEE Secti®n ~.0 ~niv~mA~L RIOT AC INTERIOR ~ EXTERIOR INSPECTION REPORT" OF. WEST THIRD STREET' RESERVOIR ",f,!(J~ , l~~ moo( iLLO~~~ ~ ATE: ~ ~- l~ ;IZED SIGNATURE ~~ TITLE OF AUTHORIZED REPRESENTATIVE: ~..... Gtr ~^i ~Aa3 -®9 ZIP ~~~ PHONE ~~s ~3~~~~ag` -1- 0 Jcal~ 2009 -2- ~' ~•® Introduction...... ............................................................ 4 2.0 Project Description.......... ............................................... 4 3•® Project _Scope_of_Services......... ........ ......... 4 - 5 ................ ~•® Submission Requirements ........ .......... .......................... 6 ~•® Proposal Submittal Information ............... ......................... 7 6.0 Bid Form,........... .......................................................... B Ap~endlx ~ Insurance Requirements ~ A~Pendi~ Project Related Data ~ 8 -3- ~.o A~TuCT~ The City of Dubuque, Water Department is soliciting competitive _pr®posals- -from- qualified Enc,~ineering__tirms to provide Interior-& E~ erior Inspection Report(s) with Corrective Action Plan(s) of the West Third Street Reservoir and Control Valve Housin Building & Pit. The West Third Street Reservoir is a circular, below ground concrete reservoir constructed in 1914 with a concrete roof, which was added in 1921. The reservoir is 180 feet in diameter and 41 feet deep with a rated capacity of approximately 7,500,000 gallons. There are 32 buttresses around the reservoir. The top slab is 7" thick and is supported by the exterior wall of the tank and 52 interior columns. The columns are braced at approximately mid-depth by concrete beams. The floor is 6" thick placed on rock. Approximately, the top 3'-0" of the tank is above ground level. The tank was designed in 1914 by Dabney H. Maury, Consulting Engineers of Chicago, Illinois. 2.0 ~ J~~T ®CR~I~°TIN Professional services for the Inspection Report and Plans for any corrective action of the Interior ~ Exterior of the West Third Reservoir and Control Valve Housing Building and Pit. 3.0 P~®J~CT ~~®~ ~ SERVICES A professional engineer (P.E.) will be present for the tank inspection. The P.E. must demonstrate extensive experience and training in concrete tank design, tank inspections, tank construction, sanitary requirements, re-coating, and repair or modifications of several tanks. This includes but is not limited to specification preparation, failure analysis and warranty inspections. The Engineering Consultant will provide the following inspection reports based on the water reservoir inspection criteria, referencing the Ten States Standards and all applicable Iowa DNR and OSHA requirements. -4- If necessary for proper inspection of the reservoir floor, sediment shall be remov ~ d ®~~ ~: Dive technicians and in-tank equipment shall be fully disinfect _ ed in accordance with AVVW,q standard 0652-02. All system entrees sh_al! be conducted in accordance with applicable OSHA regulations pertaining to Divin and Confined Space entry. g ®te 2. Complete copy of the 1988 inspection report (74 pages) is available upon request. 4.® ~U 9~~1N RE tll~E ~ T~ Before submitting a proposal, each Proposer shall make all investigations and examinations necessary to ascertain site conditions and requirements affecting the full performance of the contract and to verify any representations made by the City upon which the Proposer will rely. m6- v~~y v~ uuuUgUe Water Department C/O Jacqueline Vanek 1902 Hawthorne Street Dubuque, Iowa X2001 ® Submittal Copies: Two (2) hardcopies and one electronic (pdf) copy of the proposal shall be provided. Submit one (1) original signed proposal and one 1 co INSPECTION REPORT OF: WEST THIRD STREET RESEIRVOIR SubmEtted p opos is mi~R be delivered in printed format. In addition, supply one (1) electronic version of the proposal in Adobe Acrobat format. No faxed ore-mail proposals will be accepted. The original proposal document shall be signed in blue ink by an officer of the company who is authorized to legally bind the Proposer to its provisions. Proposals are to contain a statement indicating the period during which the proposal will remain valid. A period of not less than sixty (60) calendar days from the proposal closing date is required. Each engineering firm assumes full responsibility for delivery and deposit of the completed proposal package on or before the deadline. Any proposals received after the submittal deadline will not be considered, and will be returned unopened to the Proposer. The City of Dubuque will not be responsible for any loss or delay with respect to delivery of the proposals. The City reserves the right to reject any and ail bids or to waive any technical ties and irregularities. i3y virtue of statutory authority, a preference will be given to products and provisions grown and coal produced within the State of Iowa and to Iowa Domestic Labor. The City of Dubuque is not liable for any cost incurred by any Engineering firm prior to the execution of an agreement or contract. Nor shall the City of Dubuque be liable for any costs incurred by the firms in responding to this RFP and those not specified in any contract. Ail results from this project will remain the property of the City of Dubuque. The engineering firm must provide Proof of Insurance, which complies with the City of Dubuque's insurance Schedule C {attached). The certificate must be issued to the City before the start of the project and insurance shall be maintained throughout the duration of the contract. Thank you for your consideration and interest in the project. Sincerely, Jacqueline Vanek Wafer Treatment Plant Manager Cify of Dubuque -7- ~ ®r~ l r~ ~ r® a ~ ~ July 2009 A. ansrn~ar~a storm snspeoted B. lr~spectsori r~por# arad plans . Reservosr etentsoe~ ~sme Bid amount written out ®. Alternates > > ~ Aitemate ~9.......... . Sediment removal ................... ' ,4ltemate #2....... Sediment removal .................... signature -8- Ay ~ 'b ..............$ ~ ~ C~ ~1 ~ 760 l j';732 : " S 4 ~ ~ . ~ N fi91~ , ` ~ n`~ ~ ~ ~ ~. f ~:. ~t t - ~ , ,~ \ . , Lam, ~~ ~; -~ ~_ \t ~ X80' 1 ` ~~' ~ -- - - - - .. '~~, ~ '._ fir., r ~ C~- a, r .. ~ ~~~ ~ .,p + ~ ~ ~ ~ ~ ~.? ~~.'~ ,. ~~ ~ 285 ~ ~~ ~^ .. ~ ~ ~ t 1 ~ - F ~, ~ , ~ ~ ~'~ ~ - _i -; ~ ~ 4 _ ~ 1 Control Vaive Housing Building ~ ~ ~~-~ `t,, ~ ~ ~ ~~ ._ r'~ ~ ~ ~~ ' r t, ,. ~ y ~ ~~ `' ~~, ,t ~ ~ I ~~~ '~ ~ ~,z1 - ~~~~` ~