Loading...
Port of Dbq Design StandardsMEMORANDUM January 31,2002 TO: FROM: SUBJECT: The Honorable Mayor and City Council Members Michael C. Van Milligen, City Manager Work Session - February 4, 2002 Port of Dubuque Design Standards In November 2001, the City Council held a preliminary work session with the City's Port of Dubuque consultants. Bob Kost of URS/BRW and Anne Ricker of Leland Consulting, to review and discuss proposed land use plans and design standards for development in the 4th Street Peninsula and South Ice Harbor areas. A second work session has been scheduled for February 4, 2002, to continue the review of the proposed design standards and update the Council on revisions to the master plan. The consultants have continued to work with the 4th Street Peninsula Workgroup since the last Council work session to revise the master plan and standards. Property owner meetings have been held to review the proposals, along with reviews by architects and designers working on other America's River projects. The 4t~ Street Peninsula Workgroup was created in the Platinum Hospitality Development Agreement and consists of: Jerry Enzler, Executive Director, Dubuque County Historical Society Sue Czeshinski, Director of Convention & Visitors Bureau. Dubuque Area Chamber of Commerce Jim Rix, CEO, Platinum Hospitality Group Rick Dickinson, Executive Director, Greater Dubuque Development Corporation Bill Baum Economic Development Director Laura Carstens, Planning Services Manager Pauline Joyce, Administrative Services Manager Cindy Steinhauser, Assistant City Manager (Facilitator) The master plan and the design standards are public tools to encourage and implement new development in the Port of Dubuque. Creating standards is very important to protect the investment of Platinum Hospitality, the developer of the hotel and indoor water park, and the Dubuque County Historical Society, the developer of the Mississippi River Museum and Aquarium. Standards are also important as attempts are made to sell and develop property in the Port of Dubuque Area. Investors must be assured that their neighbors will develop and maintain their property ~n a way that will not diminish the value of their investment. Existing development in the Port of Dubuque area will have 18 months to comply with the standards, and through the Fiscal Year 2003 Capital Improvement Program Budget, it is recommended that $50,000 per year for five years be budgeted to assist owners in financing improvements. The budget Public hearing is scheduled for March 5. The public hearing, which involves the amendment to the existing Urban Renewal Plan to include design standards, will be at the March 4 City Council meeting. MCVM/jh Attachment cc: Barry Lindahl, Corporation Counsel Cindy Steinhauser, Assistant City Manager William Baum, Economic Development Director CITY OF DUBUQUE, IOWA MEMORANDUM January 29,2002 TO: FROM: SUBJECT: Michael Van Milligen, City Manager William Baum, Economic Development Director City Council Worksession: Port of Dubuque Design Standards Introduction In November 2001 the City Council held a preliminary worksess~on with the City's Port of Dubuque consultants, Bob Kost of URS/BRW and Anne Ricker of Leland Consulting, to review and discuss proposed land use plans and design standards for development in the 4'n Street Peninsula and South Ice Harbor areas. A second worksession has been scheduled for February 4, 2002, to continue the review of the proposed design standards and update the Council on revisions to the master plan. Included with this memo is the latest Design Standards booklet. Revisions to the master land use plan, based on the previous worksession with City Council, will be presented on boards at the worksession Creating standards is very important to protect the investment of Platinum Hospitality, the developer of the hotel and indoor water park, and the Dubuque County Historical Society, developer of the Mississippi' River Museum and Aquariums. Standards are also important as attempts are made to sell and develop property in the Port of Dubuque area. Investors must be assured that their neighbors will develop and maintain their property in a way that will not diminish the value of their investment The standards will apply only to the designated Ice Harbor Urban Renewal District. A map of the area is attached. We acknowledge many existing property owners will need to make improvements to their properties to implement the standards. To assist owners in financing the improvements, the recommended FY2003 Capital Improvement Program budgets $50,000 per year for five years for this purpose. Discussion The consultants have continued to work with the 4~" Street Peninsula Workgroup since the last Council worksession to revise the master plan and standards. Property owner meetings have been held to review the proposals, along with reviews by amhitects and designers working on other America's River projects. The master plan and the design standards are public tools to encourage and implement new development in the Port of Dubuque. The pdmary objectives for redevelopment include: · Capitalize on previous and upcoming public investment · Provide a mixture of uses · Build on the activity of existing and pre-planned uses · Create a pedestrian and transit oriented environment · Use downtown as a model of street and block patterning · Develop the area as a new neighborhood of downtown · Balance creative vision and market demand The proposed design standards, which are intended to apply to both new and existing development in the Ice Harbor Urban Renewal District, will ensure that the Port of Dubuque area develops as an attractive, high quality, pedestrian-oriented urban neighborhood for visitors, residents and workers. The standards provide a set of "good examples~ which will guide property developers' investment in this area. Discussion of the standards will focus on several areas that have been points of debate: Applicability/Implementation The standards will apply to all development - both existing and new - in the Ice Harbor Urban Renewal District. The design review and approval process involves submitting plans and specs to the City's Planning Services Department similar to those required of any development in the City. For existing uses, an amortization period allows up to 18 months to complete necessary modifications and improvements [o come into conformance with the new standards. This timeline is meant to coincide with the opening of the first America's River projects. The City Manager may modify the amortization schedule or the application of the standards. If a property owner is not satisfied with the City Manager s dec's on, an appeal may be made to the City Council. 2 Built Form These are the standards for the buildings and structures themselves and cover: Building setback Building height Rooflines Windows and entries Balconies and terraces Building material Accessory structures Franchise architecture Maintenance Most of the discussion centered on Accessory structures and Maintenance standards. Revisions were made to allow the use of accessory structures, although their use is discouraged. New uses should design their projects to include space within the primary building for such things as refuse, seasonal maintenance equipment, housekeeping supplies, etc. The timeline for making maintenance repairs has been extended based on discussions with property owners. Public Realm The public realm includes both public and private property along the streetscape. The proposed standards cover such things as: Sidewalks Streetscape furnish ~ngs Public art Street lighting Parking lots Landscaping Refuse and outdoor storage Fences and screen walls Signs The discussion with property owners has focused on bringing their properly up to these new standards within the 18-month amortization period. Parking lot landscaping, parking lot lighting, refuse storage, fences and signs have generated the most debate. Revisions have been made to the proposed standards eased on these discussions and some compromise has been reached. However, the standards will still affect existing properties and require them to make financial investments in their properties to upgrade certain items, especially parking lot landscaping and lighting and signage. Action Step The City Council is asked to review the proposed design standards for the Port of Dubuque and give direction to the workgroup for their finalization. Attachment CCZ Jim Rix Dave Hockenberry Rick Dickinson Sue Czeshinski Jerry Enzler Cindy Steinhauser Pauline Joyce Laura Cars[ens Mike Koch Rich Russell Parn Myhre F:\USERS\WlSaum~Port of Dubuque\portofdbq2.cc.doc DESIGN STANDARDS Port of Dubuque Master Plan Dubuque, Iowa Design Standards for the Ice Harbor Urban Renewal District Prepared for The City of Dubuque, Iowa Prepared by URS Corporation January 28, 2002 Draft TABLE OF CONTENTS Ii. BUILT FORM Ill. PUBLIC REALM !. DESIGN STANDARDS Applicability Design Review Design Approval Implementation Ground Floor Uses Minimum First Floor Elevation Building Context and Swle Vessel Context and Style Building Setback/Build to Line Building Height Ground Level Expression Roof Lines Screening of Rooftop Equipment Building Width Facade Transparency Entries Balconies and Terraces Building Maferials Architectural Detailing Parking Structures Accessory Structures/Buildings Franchise Architecture Maintenance Sidewalks and Walkways Sidewalk Landscaping Sidewalks on Parkways Sidewalks on Local Streets Walkways Accessibility and Curb Ramps Streerscape Furnishings Public Art Bike Parking Sidewalk Lighting Parking Lot Lighting Parking Lot Landscaping Surface Parking Required Off-Street Paking Refuse Fences and Screen Walls Outdoor Storage Outdoor Audio Newspaper Boxes Vending Machines Signs GLOSSARY APPENDIX Design Vocabulary Parking Lot Surface Water Run-Off Concept B/biographies Recommended Plant List Streetscape Furnishings List DESIGN STANDARDS The design standards for the Port of Dubuque have been developed to ensure that new and emsdng facilities work together to create an artracuve, high quality, pedestrian-oriented urban neighborhood for visitors, residents and workers. These standards are both prescriptive and descriptive m nature. They prescribe specific mJrfimum reqmremenrs for elements such as parking lot landscaping and signage as well as describing parameters for the design of new buildings and the remodeling of ex/sting buildings. A pictorial "design vocabular3~' ~s included to provide a set of "good" examples. Many of these maages are of facil/fies from the Dubuque metropolitan area. Failure to complywkh these design standards and procedures constitutes a violation of the Ice Harbor Urban Renewal District ordinance. Applicability These design standards apply to the following: New and existing parking facilities All sites, exclusive of their existing building or vessds, and including parking, outdoor storage and perwneters New buildings and vessels New site development Painting of 25% or more of existing building exterior Remodeling/renovation of 25% or more of existing building or vessel exterior (exclusive of roof repair) Interior remodeling/renovation of 50% or more of existing building Renovations of existing sites Expansions of existing facilities, buildings or vessels Design Review All property owners and/or developers shall meet with a representative from the City Planning Services Department to discuss the interpretation and application of these design standards to existing sites and any prospective projects to which these design standards apply. Following this meeting, a~ compliance projects, improvements, additions and new facilities shall be described in narrative text and illustrative engineering and architectural drawings, including the following:. Colored front and side builctLng elevations (1/4" scale min.) Colored illustrative site landscape plan (1:30 scale min.) Din~ensioned site plan (1:30 scale min.) Dimensioned ske l~ghting plan (1:30 scale min.) indicating proposed iJluminanon patterns and light levels Dimensioned architectural plans, including building elevations, cross sections, floor plans and details Exterior construction materials samples, including brick, stone, glazing, windows and doors, s~gnage materials, fencing, etc. These application materials shall be submitted to the Planning Services Department. Design Approval Design approval, based on a review of the application materials identified above, will be issued by the City Manager. A building permit will not be issued by the Building Services Department until such approval is given m writing. The following new facilities have been subject to comprehensive design review by the City and members of the 4th Street Peninsula Workgroup: The Mississippi River Discovery Center The Hotel/Water Park The Education and Conference Center These facil/fies form the core of the America's River project and are considered "icon proiects." In many respects, they have raised the bar and set a level of design integrity and construction quality that are the foundation of these design standards. As such, these facilities are exempt from the Built Form section of these standards. Implementation Application of these design standards to new facilities shall be effective as of ~st date). Application of these' design standards to emsdng facilities shall be effective as of (list date) and shall be implemented according to the following 18 month schedule: 0-6 months Conduct property review meedng with the Planning Services Department. 6-12 months Submit necessary plans and information describing compliance plans and improvements to the Planning Services Department. 12-18 months Complete necessary modifications and improvements. The City Manager may modif7 the schedule or application of these standards. A property owner who is aggrieved by the City Manager's decision shall apply to the City Council for review thereof. The City Council may modify such schedule or the application of these design standards. Ground Floor Uses In order to promote street hfe and pedestrian actiwty, at least 60% of the ground floor facing Bell Street and 5th Street shall be comprised of commercial, retail, entertainment, restaurant or business service uses, !!. BUILT FORM Minimum First Floor Elevation To ensure that development is built consistent with district-wide storm detention parameters, the minimum ftrst floor elevation of all new buildings and structures shall be set at an elevation of at least 605.5 feet, Building Context and Style New buildings should relate to the tra&tional buildings common in the downtown. This can be ach/eved by maintaining alnfilar setbacks, building scale and height, cornice lines, fenestration patterns, architectural styles and details, building materials and colors. The preva'~ng building vocabularies in downtown Dubuque are traditional "main street" style commerdal structures up to four stories, five to ten-story office buildings with ground floor commercial uses designed in a variety of classical revival styles, mid-rise, warehouse style manufacturing facilities and residential row houses up to four stories, predominantly in French and Italian rev/val styles. Although new buildings may be designed in a variety of styles, they should draw upon the design features found in existing, exemplary downtown structures. These features are illustrated in the Design Vocabulary in the Appendix. Vessel Context and Style Vessels to be used as a primary facll/ty or moored in the Ice Harbor on a regular basis should relate to the vessels commonly found in the Ice Harbor area. The prevailing vessel vocabularies are traditional, rivercraft such as paddelwheel steamers. New vessels should be compatible with this prevaJJing vocabulary. Building Setbaclq Build-to Line New buildings shall meet the defmed public sidewalk line except for small setback areas (10-15 feet in depth) to create entry courtyards, patios, or outdoor seating, dining and gathering areas. New residential buildings shall be set back from the~publlc sidewalk 1/ne or right of way a minimum of 10 feet and a maximum of 20 feet ro provide semi-private transiuon space between the public street and the front entry. Building Height Building heights shall vat3, based on their proximity to the water front, with taller buildings located adiacent to the river and the harbor to capitalize on views and maximize land values. Waterfront New buildings adjacent to the Ice Harbor or Mississippi River shall be a minimum of 3 stories (36 feet) and a maximum of 10 stories (112 feet) in height. Non-waterfront In general, non-waterfront buildings shall be a minimum of 2 stones (22 feet) up to a maximum of 10 stories (112 feet) in height. New free-standing restaurants and office-showroom buildings may be of one-story construction and shall be no less than 22 feet in height to the top of the front and side cornice lines, Any new building located accross Bell Street from the Education and Conference Center shall not obscure the view of the dome of the historic County Courthouse as viewed from inside the central corridor of the Education and Conference Center. Ground Level Expression In commercial, office and mixed use buildings, the ground floor shall be distinguished from the floors above by the use of one ar more of the following elements: horizontal banding, an intermediate cormce line, a change in building materials, an awning or an arcade. 22 feet Setback along side~valk line to provide enrr~ wurt and outdoor seating area. Single sto~ building a~ith 2 sto~ co~ice height. Examples of effective d~rentia~on betmeen $munkfloor and upper kvels. Roof Lines Flat roofs are the most common and traditional roof form. New buildings should use flat roofs, although gable, hip ot traditional mansard roofs are permitted. On fiat roofs, rooftop terraces, decks and gardens are encouraged, ro provide views to the river and cit3,scape and improve the view from taller, adjacent structures. Arbors or other roof top structures may be exempt from height resmcdons if they meet the following Conditions: Screening of Rooftop and Mechanical Equipment _~1 mechanical equipment shall be screened from street frontage view with materials that are architecturally compatible with the primary building hcades. Screening provided by the roof structure or by other arch/tectural elements is preferred. Rooftop eqmpment may also be screened by a smaller accent roof or enclosure. If this structure is set back from the primary facade a distance equal to its height, this structure may exceed the building height limit. Building Width Non-residential buildings more than 30 feet in width shall be divided into smaller increments through articulation of the facade. This can be achieved through a varmty of techniques such as the following: Divisions or variations in materials (although materials should be drawn from a common palette) Window bays Separate entrances and entry treatments or pordcos Variation in roof lines Awnings Vananons in brick or stone work Colonnade or arcade A maxLmum height of 12 feet above the roof deck A setback from all building facades fronting a public street of at least 10 feet or equal to the structure's height, if greater Enclosed structures shall cover a no more than 20 percent of the roof area Arbors or other vertical "open" structures shall cover a maximum of 80 percent of the roof area Exampks of rooftop equipment screening. Rooftops &veloped as useabk outdoor q)aoe. Large buildings effeciivle3 broken domn to smaller,Oedestrian scale increments. Facade Transparency Where commercial or office uses are located on the ground floor, a mum of 25 percent of the ground level facade fronting a publ/c street and a mm/mum of 20 percent of the gromad level side and rear facades shall consist of either windows or doors to allow views into and out of the building~s interior. A minimum of 15 percent of the front, side and rear facades of all upper floors of office uses shall be transparent via windows and/or balcony doorways. A minimum of 10 percent of the front facade of all upper floors of commercial, rettdl, restaurant and entertainment uses shall be transparent via windows and/or balcony doorways. Entries The main entrance shall always face the prmtary street or street corner with secondary entrances to the side or rear The main entrance of commercial, office, and mixed-use facilities shall be placed at sidewalk grade. Balconies and Terraces Upper floor balconies and terraces are encouraged to provide opportunities fo~ outdoor activities, providing views and enl/vening the port area. Balconies fronting publ/c streets may project into the public right of way/sidewalk zone a maximum of 5 feet. Balcony supports such as columns or posts are not permitted in the public right of way. Under no circumstances may balconies project into the travelway. Effedive use of ground kvel and upper kvd tran¢aren~y. W/ell defined and accessible em~yrvqs benefit vistors aM business omners. Terraces and balconies enhancepublic safe~ and enliven the streetscape. Building Materials Buildings shall be constructed of authentic, long lasting materials such as concrete, wood or steel and dad in brick, stone, stucco, and/or architectural metal. Accent materials may include architectural metal trim and panels, glass block, pre-cast concrete, splitfface or fractured concrete block, or similar decorative or unique materials. EFIS or smcco shall comprise no more than 20 percent of any building exterior and shall be located a minimum of 3 feet above grade to prevent discoloration from rain, snow, etc. Wood or synthetic wood lap siding may be used on residential building types only, up to a maximum of 20 percent of the first story and 50 percent of the upper stories. The following bdlding materials and building systems are prohibited: unadorned or painted standard concrete block pre-fab "tilt-up" concrete wall panels vinyl, aluminum or fiberglass panel and lap siding highly reflective or non-transparent glass standard, 3-tab, 2701b asphalt shingles manufactured metal pole-barn type facilities Architectural Detailing Architectural detailing is encouraged to enliven building facades, establish a human-scaled, pedestrian.supportive environment. Architectural design shall be sensitive to the massing and proportion of adiacent structures and reflect or compliment the detailing of surrounding bukldings, such as lintels, cornice lines, balconies and decorative brick or stone work. Parking Structures Parking decks and ramps shall be designed in compliance with these design standards in order to appear compatible with and similar to other nonresidential buildings: The ground floor facade abutting any public street or sidewalk shall be designed and architecturally detailed to resemble a commercial/office building. Where possible, a portion of the ground floor abutting a public street or sidewalk should include commerdal or office uses. The design of upper floors shall ensure that sloped floors do not dominate the appearance of the facade. Windows or opermags shall be provided that echo those of nearby buildings and the Design Vocabulary. D)nestone and face bffck are commonly used building mate~iah in Dubuque. Parking structure mith commerdal storefronls. Accessory Structures / Buildings Use of an accessory structure or accessory building for new office, commercial service and residential facilities is prohibited. These facilities shall include a sufficient amount of storage space for the suitable storage of such things as refuse, seasonal maintenance eqmpment, speeiai event equipment, housekeeping supplies, etc. Use of an accessory strucmre/bnilding for existing facilities is discouraged. New free standing restaurants, mixed u§e facilities which include commercial food service or restaurants over 1,500 gross square feet may locate their refuse containers in an accessory structure or accessory building. The design of the accessory structure shall be in character with the principal building and constructed of the same quality permanent materials as the principal bnilding. The accessory structure shall be located on the same lot and within close proximk7 to the principal structure. Where such buildings exceed 200 square feet in area, at least 1/3 of the bullding's exterior perimeter shall be landscaped with ornamental trees and shrubs. Franchise Architecture Maintenance Franchise architecture (building design that is trademarked or identified All facilities, including vessels, within the Port of Dubuque shall exhibit with a particular chain or corporation and is generic in nature) is an exceptional standard of care and quality of appearance. To that prohibited. Franchises or national chains must follow these guidelines end, all properties (buildings, parking lots, landscaping, etc.) shall be and use the Design Vocabulary to create a unique building that is maintained in excellent repair at ail times including but not limited to: supportive of the overall urban context being established at the Port of Dubuque. Exterior materials Exterior paint Windows and doors Awnings and canopies Roofing systems Eaves and cornices Chimneys Mechanical and electrical sysmms Exterior walkways Surface or structured parking facilities Exterior lighting Automatic landscape irrigation systems Trees, shrubs, flowers, lawns and mulch material Building and site signage Fences and screening or retaining walls · ~".~ ' Facilities shall receive regniar maintenance with replacement and repairs budgeted and scheduled over the life of the facility. Minor building and site repairs shall be made as soon as reasonably possible (within maximum of 30 days) after the discovery of a malfunction, failure or noticeable deterioration. . Major building and site repairs shall be made as soon as reasonably possible after the discovery of a malfunction, failure or noticeable Tjrpical franchise architecture ~ unarceptable, deterioration. Unhealthy or dead landscape plantings and lawn shall be removed as soon as reasonably possible (within maximum of 7 days) and replaced with suitable new plant materials at the earliest practical time (within maramum of 9 months) based on the appropriate season. Compatabk accessory siructure. Acceptabk franchise design uiilixineg contextual, community ¢edfic architecture. I!1. PUBLIC R£ALM Sidewalks and Walkways Pedestrian accessibilitT and continuity shall be provided throughout the area. Continuous sidewalks a minimum of 5 feet wide shall be provided along all pubhc street frontages. Clearly defined and lighted pedestrian walkways shall extend oerween parking areas and all building entrances. Sidewalk Landscaping Street trees shall be planted within a landscaped boulevard or in tree pits within the sidewalk area according to City standards. Street trees shall be spaced between 30 and 40 feet apart. Street trees planted within the sidewalk area shall be planted using the latest, most advanced horticultural techniques such as "CU Structural Soil," drip irrigauon, etc. Where buildings front the sidewalk (such as commercial, office and mixed use facilities) planter pots, planter boxes or hanging planter baskets shall be included and integrated into the buildings' design ro provide seasonal color and enhance the pedestrian experience. Where present, all front yard areas shall be landscaped with trees, shrubs, ground cover, and turf grass. Sidewalks on Parkways Public sidewalks on parkways shall be a minimum of 8 feet wide, and constructed of integrally colored concrete, scored in an alternating band and panel arrangement and textured with both a smooth and medium broom finish. Joints shall be troweled not saw cut. Sidewalks on Local Streets Public sidewalks on local streets shall be a minimum of 5 feet wide and constructed of concrete a minimum of 4 inches thick over a 4 inch deep compacted aggregate base. The surface shall consist of broom £mish center field surrounded by smooth steel-troweled edge bands. Joints shall be troweled not saw cut. Walkways Walkways in parking areas, around buildings or on private properties shall be a minimum of 4 feet wide and constructed of either colored concrete or brick pavers. Bitunainous wallovays are prohibited, Accessibility and Curb Ramps All sidewalks and walkways shall meet the Americans with Disab/lities Act (ADA) standards for accessibility. Where curb ramps are provided, the3, shall comply with City standards and shall direct pedestrian flow in a continuous manner. They shall be constructed of integrally colored concrete, scored in a one foot square grid pattern and textured in a stiff broom finish. 5' 51P WA!.K- 8' 51P W, ALK Expanded full corner curb ramp Jbr use at high pedesMan traffic areas. 11. Streetscape Furnishings Publ/c rights-of-ways within the Port of Dubuque will be designed to provide visitors (~edestrians, bicyclists and motorists) with a safe, converfienr, comfortable and attractive environment to circulate through and inhabit The public streetscape w/ll serve as an outdoor room where social discourse and exploration combine with vehicular accessibility and mobility. To that end, a family of attractive, durable, benches, litter receptacles, bike racks, dkectory kiosks, and light f~xtures are proposed to be located along the streets, parking areas and parks and plazas. (see appendix for product deaifitions) Public Art The use of public art to enliven and enrich the public and sem/-public realm is encouraged. Consideration should be given during the site planning and project review phases to incorporate works of public art into the overall design of a particular development project. Proposed public art works shall be subject to the same review and approval procedures as described herein. Outdoor Cafe Tqbk and Chair Painted Metal W/oven Seat Bench LiiterRecep~¢al 1 ArXist Carved Granite Bench Artist Cast Utility Cover Parking Lot Lighting Painted Metal Bench IVood Bench La'lter Recep tical 2 12. Bike Parking Bike loops for parking at least 3 bicycles shall be provided within 20 feet of the main entry of commercial, mixedmse and public build/ngs. 31PE:DIRECTBURYIN CONCRETE ~CONC.SIDEWALK COMPACTED SUB GI:~,D E Painted bike loops Sidewalk Lighting Public sidewalks and private walkways shall be l/luminated with pedestrian scale light fixtures (12 feet tall). Illumination shall be provided by metal hal/de lamps arranged to produce a fakly even distribution of light at levels of approximately one footcandle. See appendix for light fixture i~rma~ion, Parking Lot Lighting All surface parking lots shall be provided with even illumination to a minimum of three and a maximum of five footcandles. Illumination shall be accomplished with a combination of commerdal grade parking lot and pedestrian st34e fmmres. Pedestrian fixtures shall be used for lighting internal parking lot walkways while parking lot £zxtures shall be employed to ~uminate parking bays and drive aisles. The commercial grade parking lot fixtures shall be comprised of circular "hat-box" or "hockey puck" st34e lumina[res in either single or double sets, attached to 24 feet tall, tapered metal poles by horizontal arms. Fixtures shall util/ze metal halide lamps. Light poles located within parking bays shall be mounted on 2 foot high, limestone patterned, integrally colored concrete bases. £ingle globe street and ~valk~vay ligh~ Doubk luminaire "hatbox"parking lot light on limestone fia#erned concrete base. 13. Parking Lot Landscaping A landscaped buffer strip at least 7 feet wide shall be provided between all surface parking areas and the sidewalk or street. The buffer strip shall consist of shade trees, low shrubs and/or perennial flowers (3 feet in height max.), and a decorative metal fence no more than 4 feet kigh supported between decorative masonry columns. Landscaped earth berms are not permitted and sh~ not substitute for the landscape screening described above. Use of bio-filtration methods of landscape and drainage design are encouraged.* A landscape buffer at least 7 feet wide shall be provided along the rear and sides of all surface parking lots. This area shall be planted with shade trees, coniferous trees, and a continuous 4 foot tall shrub border or hedge of deciduous and/or evergreen shrubs. Parking bays in excess of eleven spaces in length shall be divided by intermediate landscape islands. Landscape islands shall provide at least one parking stall width of landscape area (9 x 18 or 9 x 36 feet for single or double bay 90 degree parking). A minimum of one shade tree or two ornamental trees, low shrubs and/or perennial flowers shall be planted in each intermediate planting island. Double parking bays shall terminate with planting areas of a minknum of a double parking space of landscape area and shall be planted with a mmmaum of two shade trees, shrubs and/or perennial flowers. All new parking lot landscaping shall comply with City standards, be mulched to a depth of 4 inches with a high qualit3; freely shredded hardwood mulch and shall be watered by an automauc, underground irngarion system. Surface Parking Off-street parking lots shall be designed and constructed utilizing dvil engineering "best practices." At a minimum, surface lots shall be paved with asphaltic concrete over a compacted aggregate base with edges and planting islands defined by concrete curb and gutter and parking spaces de£med with painted striping. Parking on gravel, dirt or unreinforced turf is prohibked. Off-street parking shall be located to the rear and/or side of buildings. Front-yard parking ~s permissible oniy along a maximum of 20 percent of the total site frontage. When parking or parking access must be located in the front yard, a landscaped buffer shall be provided (see "Parking Lot Landscaping"). Examples of mell landscapedparking areas. ~ (',~ee appendi,5;') SUPPORTEO BY MASONRY Off-Street ,Parking Requirements The intent of this section is provide flexibility in the determination of the number of off-street parking space required ro meet the rninimum needs of each proposed building or use while taking toro account the efficiencies inherent in the differing peak demand requrrements of these uses and the overall sharing of parking facilities between uses. Furthermore it shall be understood that there are existing shared parking agreements in place which may require amending in order to accommodate and facilkate the addition of new buildings and uses. The number of off-street parking spaces required for each building or use shall be determined through the design review process for each individual project. Refuse Outdoor placement of free standing dumpsters or refuse containers is prohibited. Refuse shall be securely stored and enclosed as part of the principal structure, and contained and disposed of in accordance with applicable state, county and city health, safety and environmental codes. Use of sealed compactors is encouraged. Where food service/restaurant kitchen refuse storage is not accommodated as parr of the principal building, refuse storage is permissible in an accessory storage enclosure See Accessory Structures/Buildings) BUFFER STRIP LANDSCAPED ISLAND 18'X9' (162 FT2 MIN, TYF. LANDSCAPED ISLAND 3B'Xg' 1324 FT2 MIN. T'? p. } Decoralive fence be~veen public sidewalk andparkh~g. Example of a&quate parking lol landsape layout 14. Fences and Screen Walls All fencing and screen walls shall be designed to incorporate intermediate structural components in order to avoid a front and back side. Fencing and screen walls shall be attractive from all views. Residential Uses Fencing placed in front yard areas between the sidewalk and the building shall be up to 42 inches in height. The following materials are acceptable in front yard locations: Painted architectural metals, including heavy gauge metal mesh in a square or rectangular configuration, with a painted metal frame. Fendng may be mounted on decoranve masonry wall of brick, stone, or architectural precast concrete units. Total height of wall and fence shall not exceed 42 inches. Masonry walls shal/be of durable, permanent construction. Dry-laid or stacked construction is not permissible. Unacceptable materials for front yard residential include: Wood fencing of any kind. Chain link fencing. Fiberglass or plastic pickets or panels. Rear or side yard areas may have privacy fencing up to 6 feet m height. Acceptable materials for rear and side yard residential include: Solid wood board panels of rot-proof ltmaber such as cedar, teak, or treated pine. Decorative wood lattice may occupy the top portion of the fence up to a maximum of .18 inches. Painted wood or plastic picket fencing. Any of the acceptable front yard fence and/or wall materials. Unacceptable materials for rear and side yard residential include: Chain link fencing Fiberglass or plastic panels Plywood or chip board panels Corrugated or sheet metal panels Office and Commercial Uses Decorative fencing for office and :ommercial uses m areas facing the primary street, such as entry court3,ards or outdoor searing areas, may be located between the building and the sidewalk. Fencing in these areas shall be limited to the following: Painted architectural metals, including heavy gauge metal mesh in a square or rectangular configuration, with a painted steel frame. Fencing may be mounted on decorative masonry wall of brick, stone, or architectural precast concrete units. Total height of wall and fence shall not exceed 42 inches. Masonry walls shall be of durable, permanent construction. Dry-laid or stacked construction is not permissible. Unacceptable materials for front areas of office and commercial include: Wood fencing of any kind. Chain link fencing. Fiberglass or plastic pickets or panels. Corrugated or sheet metal panels. Commercial or oflce findng exampks. Residenfial fendneg example~. Pre-Development Temporary Fencing Existing uses that require screening for outdoor storage and mechanical equipment shall be a minimum of 8 feet in height, with a maximum height of 10 feet. Acceptable materials include: Solid wood panels - painted or stained and sealed Fabric Unacceptable materials for temporary screening include: Chain link fence Fiberglass or plastic panels Corrugated or sheet metal panels. See Parking Lot Landscapingfor fendng in parking lot areas. Outdoor Storage Outdoor storage of any kind including vehicles, raw materials, etc. is prohibited. Seasonal equipment, supplies, etc. shal/be either stored within each facillt3, or within a permanent accessory structure. (See Accessory Structures/Buildings) Outdoor Audio Music, public address announcements and other forms of outdoor audio are discouraged. Sound shall be contained within the site boundaries. Outdoor music or other forms of outdoor audio associated with special events shall be controlled by the City's regulations for special events. Newspaper Boxes Newspaper dispensing units shall be clustered in small groups (2 or 3) and be ground mounted, not chained or strapped to other streetscape elements. Vending Machines Outdoor placement of vending machines including but not limited to beverages and snacks is prohibited. Vending machines shall be located indoors, Signs Building and vessel signs should be arch/tecturally compatible with the style, composition, materials, colors and details of the building or vessel. Signs should be an integral part of the building and site design. A comprehensive sign program should be developed for buildings or vessels which house more than one business. Signs should be compatible with one another. No more than two t3~pes of signs should be used on a single building facade or vessel (i.e. wall signs, projecting signs, awning signs). Sign Location: Wall s~gns on commercial or mixed-use storefront- t3q?e buildings should be placed w/thin a "sign band" immediately above the storefront display windows or enu3rway. Wall signs on other building types should be placed where they do not obscure architectural features. Sign Materials: Sign materials should be consistent or compatible with the construction materials and architectural style of the building facade on wl-rich they are to be displayed. Neon signs are permissible for display windows. Sign Illuminauon: Both internal and external ~llumination of signs, except for awnings, is permissible. The following s~gn t3~es are prohibited: Pole or pylon signs Billboards Internaily illuminated awmngs Flashing and roradng signs Portable signs Search I/ghts Audible or musical s~gns Roof Signs The following sign types are permissible: Non-illuminated awning s~gns Canopy or marquee signs Wall signs Projecnng signs Window signs Freestanding ground/monument signs Freestanding non-flashing, electronic information or message signs* * (Limited lopublic and institutional uses such as a convention center or museum) ProjectLng Signs: Maximum dimensions for projecting signs: 9 square feet, with a clearance of at least 8 feet from ground level, prolecting no more than 3 feet from the side of the building. Window Signs: Window signs should cover no more than 10 percent of the window area. Directional Signs: Dkectional signs shall be limited to 6 SF per sign and allowed as needed subject to overall the review and approval of a comprehensive sign plan. coordinated tva//and awning sxgns. 16, Freestanding ground/monument signs: Freestanding ground/monument signs shall be limited to use by commercial and institutional establishments such as hotels, restaurants, gas stauons, museums, ere. Sign design materials, colors and detailing should be similar to those of the principal building. Maximum dimensions for ground/monument signs: 19 feet high by 7 feet wide by 5 feet deep. Maximum sign message any one side: 95 SF Maximum total sign message area all sides: 250 SF Electronic Message Signs: Maximum of 1 sign per facility. Maximum sign size: 75 SF Wall Signs: Maximum dimensions for commercial / retail wall signs: 2 feet high, 50 SF of sign message per use/occupant. Wall signs shall be limited to no more than 3 colones. Where multiple messages such as a series of occupant names are displayed on a sign band that extends across the building, the text should be one CO1OL Restaurant, nightclub or entertainment facility wall signs: Maximum of 2 wall signs per use, on sepazate walls Maximum total s~gn area per use: 100 SF Maximuna total sign area per building, all uses: 400 SF Hotel, gaming and institutional or pubhc building wall signs: Maximum of 2 wall signs, per use on separate walls Maximum sign size: 250 SF Maximum total sign area for all wall signs: 500 SF Cinema and theater signs: Marquee sign: maximum 3 sides, maximum 300 SF of changeable information area plus 150 SF of identity signage Maximum of 2 wall signs, on separate walls Maximum size of wall sign: 32 SF Maximum total sign area for all wall signs (not including marquee sign): '64 SF Vessel signs: Maximum area based on 50% of vessel length (100 foot length = 50 SF maximum per s~gn) Maximum of 2 signs (not including official Coast Guard required vessel name display) 17. GLOSSARY Accessory Building: A subordinate building, located on the same lot as the main building, or a portion of the main building, the use of which is clearly incidental to and customarily found in connecuon with the mare building or principal use of the land. Arbor: A rooftop or garden structure which provides shade. Arcade: A roofed passageway, usually with shops on one or.both sides. Building Frontage: The front facade of a building, typically abutting the sidewalk. Cornice: Any prolecting ornamental moulding along the top of a building Eaves: The underpart of a sloping roof overhanging a wall. EFIS (Exterior Finish Insulation System): A coating of cementidous, stucco-like material over rigid insulation. Entertainment Facility: A business engaged in the provision of legal activities or performances for the enjoyment. Franchise Architecture: Building design that is trademarked or identified with a particular chain or corporation and is generic in nature. Infiil Building: A new building sited within an established neighborhood, often between two exisung buildings. New Building: In addition m actual new buildings, the term "new building" shall include any expansion of an erasting building that equals or exceeds 50 percent of the original building's floor area and shall also include buildings which are the subject of substantial material and comprehensive renovation. Parapet: A low, decorative wall or rafting along the edge of a roof Gable Roofi A pitched roof with a central ridge hne and vertical wall ends. Gambrel Roofi A roof with a double pitch terminating in a small gable at the ridge Hip Root A pitched roof with sloped instead of vertical ends. Mansard Roof.' A pitched roof having a double slope, the lower pkch being longer and steeper than the upper. Office / Showroom: A product display or showroom facility with two prLmary uses: office and showroom/display space. Storage, light assembly or shipping and receiving may occupy no more than 20% and office use may occupy no more than 75% of the facility's gross floor area. Primary Facade: The facade fronting a public street. In the case of corner buildings, the primary facade fronts the highest classification of street. 1) Any exterior remodeling and/or site alteration of 25% or more of any existing vessel, commerdal, office, multi- family or institutional building or structure; or 2) any exmrior remodeling that dearly alters the appearance of such a building or structure, including change in exterior paint color or material; or 3) any mmrior remodeling/renovation of 50% or more of existing vessel deck or building floor area. Service Commercial: Commercial uses that are primarily oriented to service rather than retail sales, such as barbers, photocopying, photo development, dry cleaners, shoe repair, etc. Sidewalk Line: The outer edge of the sidewalk, where the front facade of a storefront building is typically located. Storefront Building: A commercial building located at the sidewalk line, with display windows and principal entry on the ground floor facing the sidewalk. Storefront bugdings typically include traditional elements such as a sign band above the storefront, a transom, a recessed entry and a kickplate as a base m the storefront. Streetscape: The public right of way, from building face to bulldMg face, occupied by the street, boulevard, sidewalk and pedestrian amehides such as lighting, benches, bike racks, etc. Urban Context Building Massing & Proportion t' il MaterialSl :~ & C olo:': ~' Buildi Oraam & Deta Design Vocabulary Entries Windows Building Signs ~; .~-.,- Awnin Site Si Design Vocabulary Street & Sidewalk Streetscape Elements Streetscape Element's, Transit facilitie Design Vocabulary Parking Design Vocabulary Sp' Open a Parking Open CONCEPTUAL SECTION / ELEVATION OF VEGETATIVE SWALE FOR PARKING AREAS URBAN TOI .F, RANT SHADE TREES NATIVE GRASSES, SEDGES & WILDFLOWERS COLORED CONCRETE--~ EDGE, 3' WIDTH DIRECTION OF SURFACE DRAINAGE MIN. 2' WELL DRAINED, COURSE PLANTING SOIL 12" SAND BED* FILTER FABRIC 8" PEA GRAVEL LAYER* CORRUGATED- PERFORATED DRAINTILE TO STORM SEWER ~ All Dimensions are approximate, final design shall be based on design storm evens and existing subsurface soil characteristics / / / / / / / / / / BUTTERFLY WEED LIATRUS MARSHALL SEEDLESS ASH INDIAN GRASS BLACKEYED SUSAN SWALE CONSTRUCTION VEGETATIVE SWALE VEGETATIVE SWALE APPENDIX Bibliographies Bart Engineeting Company. 2001. Minnesota Urban Small Sites BMP Manual; Stormwater best management practices for cold climates. Metropolitan Council Environmental Services. Available from the Metropolitan Council at 651-602-1000 or www. metrocouncil.org. Claytor, Richard A. and Thomas R. Schueler. 1996. Design of Stormwater Filtering Systems. Chesapeake Research Consortium. Available from The Center for Watershed Protection at 410-461- 8323 Minnesota Pollution Control Agency. 2000. Protecting Water Quality in Urban Areas; Best management practices for dealing with storm water runoff from urban, suburban and developing areas in Minnesota. /Wmnesota Pollution Control Agency. Available from the MPCA contact Mary Osborn at 651-296~7523 Recommended Plant List Trees Autumn Blaze Maple River Birch Hackberry Marshall Seedless Ash Acer x freemanii ~Jeffers Red' Betula nigra Celfis occidentalis Fraxinus pennsylvanica 'Marshall's Seedless' Shrubs Black Chokeberry* Isanti Dogwood* Smooth Wild Rose Meadowsweet Western Snowberry Aronia melanocarpa Comus sericea 'Isanti' Rosa blanda Spiraea alba Symphoricarpos occidentalis Grasses Bebb's Sedge Fox Sedge Soft Rush Torrey Rush Litde Bluestem Prairie Dropseed Carex bebbii. Carex vulpinoidea Juncus effusus Juncus torreyi Schizachynum scoparium Sporobotus heterolepis Flowers Yarrow Marsh Milkweed Alert Red Aster New England Aster '~ Joe Pye Weed = Meadow Blazing Star Great Blue Lobelia Bee Balm Obedient Plant Black Eyed Susan Spiderwort Culver's Root* Golden Alexanders Achillea 'Moonshine' Asclepias incarnata Aster novi-belgii 'Alert' Aster novae~angliae Eupatotium maculatum Liatris ligulistylis Lobelia siphilitica Monarda didyma 'Marshalls Delight' Physostegia virginiana Rudbeckia fulgida 'Goldsturm' Tradescanfia ohiensis Veronicastrum virginicum Zizia aurea "Plants that should be reserved for buffer and screening areas because they grow over 3 feet in height and may inhibit surveillance. Streetscape Furnishings List The following products are preapproved by the City for use at the Port of Dubuque; however, it shall be understood that the items listed are all subject to an "or equal" review process. Product substitutions of equal design, quality and performance are permissable per the review and approval of the City. Cafe Table: "Steelhead" 36" table top with "Catena" surface mount base, Grotto powdercoat, Landscape Forms, Kalamazoo MI Phone: 800-521-2546 Cafe Chair: "Verona" without armrests, Grotto powdercoat, Landscape Forms, Kalamazoo, MI, Phone: 800-521-2546 Painted Metal Woven Seat Bench: "Scarborough Backed Bench" 72" long, Grotto powdercoat, Landscape Forms, Kalamazoo, MI Phone: 800-521-2546 Litter Receptacle 1: "Scarborough" receptacle, side opening, Grotto powdercoat, Landscape Forms, Kalamazoo, MI Phone: 800-521-2546 Artist carved granite bench example: Stanton Sears for the City of Minneapolis, Nicollete Mall Renovation Artist cast iron utility cover example: Kate Burke for the City of Minneapolis, Nicollete Mall Renovadon Parking Lot Light Fixture: "Form Ten" round, arm mounted luminaire by Gradco, CA 22" Style with 250 watt Metal Halide lamB single or double head on a straight 4" round steel 25' pole, powdercoat RAL 9017 (black) smooth gloss £mish. Painted Metal Bench: "Hyde Park" model# HP3005-BS~75, metal rod seat, Grotto powdercoat, Landscape Forms, Kalamazoo MI,Phone:; 800~521-2546 Wood Bench:"Givemey" bench 6' model #U5547 by Smith and Hawken Novato, CA, Phone:800-423-0117 Litter Receptacle 2: "Presidio, top-opening" Grotto powdercoat, Landscape Forms, Kalamazoo MI, Phone: 800-521-2546 Street and Walkway Light: "Lumec" single acorn globe minimum 100 wat~ Metal Halide lamp on traditional I2 foot tapered steel pole, Powdercoat RAL 9017 (black) smooth gloss finish, model # L52 L/vIS 13004A APPENDIX