Loading...
Code of Ordinances Amendment - Title 14 International Residential Code Copyright 2014 City of Dubuque Action Items # 10. ITEM TITLE: Code of Ordinances Amendment- Title 14 International Residential Code SUMMARY: City Manager recommending adoption of the International Residential Code. ORDINANCE Amending City of Dubuque Code of Ordinances Title 14 Building and Development, Chapter 1 Building Codes, Article B Residential Code, Sections 14- 1 B-1 International Residential Code Adopted and 14-1 B-2 International Residential Code Amendments by Repealing Such Sections and Enacting New Sections in Lieu Thereof Adopting the 2015 International Residential Code SUGGESTED DISPOSITION: Suggested Disposition: Receive and File; Motion B; Motion A ATTACHMENTS: Description Type International Residential Code-MVM Memo City Manager Memo Staff Memo Staff Memo Ordinance Ordinance Suggested Motion Supporting Documentation THE CITY OF Dubuque UBE I erica .i Masterpiece on the Mississippi 2007-2012-2013 TO: The Honorable Mayor and City Council Members FROM: Michael C. Van Milligen, City Manager SUBJECT: Adoption of the 2015 International I-Codes DATE: June 1, 2016 The City of Dubuque has traditionally adopted the new International I-Codes every three years. The adoption of the 2015 International I-Codes allows the City's inspection staff to properly perform their duties during the plan review process, field inspections, and upon completion issuing the Certificate of Occupancy, making sure all structures are safe and meet minimum code requirements. The City of Dubuque will also benefit from the adoption of the new I-Codes through the Insurance Services Organization (ISO) Building Code Effectiveness Grading Schedule, which provides communities with an overall score based on the effectiveness of adopted Building Codes. This score is then analyzed by insurance companies and others to help determine property insurance rates locally. Building Services Manager Todd Carr recommends City Council adoption of the following 2015 International I-Codes: 1. 2015 International Residential Code 2. 2015 International Building Code 3. 2015 International Mechanical Code 4. 2015 International Plumbing Code 5. 2015 International Fuel Gas Code 6. 2015 International Energy Conservation Code I concur with the recommendation and respectfully request Mayor and City Council approval. Micliael C. Van Milligen MCVM:jh Attachment cc: Barry Lindahl, City Attorney Cindy Steinhauser, Assistant City Manager Teri Goodmann, Assistant City Manager Todd Carr, Building Services Manager Dubuque Building Services Department THE CITY OF 50 West 13th Street Dubuque,Iowa 52001-4805 DuB 11 Mx�1ceC ' Office(563)589-4150 I I I I Fax(563)690-6687 TTY(563)690-6678 building@cityofdubuque.org Masterpiece on the Mississippi www.c yo£dubuque.org 2007.2012.2013 TO: Michael C. Van Milligen, City Manager FROM: Todd Carr, Building Services Manager SUBJECT: Adoption of the 2015 International ]-Codes DATE: June 1st, 2016 Introduction: The purpose of this memorandum is to provide you with information and request adoption of the 2015 International I-Codes to replace our current 2012 International (- Codes. The following 2015 International I-Codes are proposed to be adopted. 1. 2015 International Residential Code 2. 2015 International Building Code 3. 2015 International Mechanical Code 4. 2015 International Plumbing Code 5. 2015 International Fuel Gas Code 6. 2015 International Energy Conservation Code Background: The City of Dubuque has traditionally adopted the new International (- Codes every three years. The International Code Council who composes the I-Codes every three years works with registered voting members from many different private and public sectors during the adoption process of the new I-Codes. As a group they review the Codes every three years, taking into consideration many different factors as they amend, delete, change, or alter existing code language along with composing new code language as needed. Discussion: The adoption of the 2015 International I-Codes allows our inspection staff to properly perform their duties throughout the plan review process, field inspections, and upon completion issuing the Certificate of Occupancy, making sure all structures are safe and meet minimum code requirements. The City of Dubuque will also benefit from the adoption of the new I-Codes through the ISO Building Code Effectiveness Grading Schedule, which provides communities with an overall score based on the effectiveness of adopted Building Codes. This score is then analyzed by insurance companies and others to help determine property insurance rates locally. Service People Integrity Responsibility Innovation Teamwork Conclusion: The adoption of the 2015 International I-Codes will replace our currently adopted 2012 International I-Codes. Action Step: I respectfully recommend the adoption of the new 2015 International (- Codes. I request that the ordinance is reviewed and forwarded to the City Council for consideration and approval. Please let me know if you have any questions. Cc: Crenna Brumwell Barry Lindahl Prepared by: Crenna M. Brumwell, Esq. 300 Main Street Suite 330 Dubuque IA 52001 563 589-4381 ORDINANCE NO. 27-16 AMENDING CITY OF DUBUQUE CODE OF ORDINANCES TITLE 14 BUILDING AND DEVELOPMENT, CHAPTER 1 BUILDING CODES, ARTICLE B RESIDENTIAL CODE, SECTIONS 14-1B-1 INTERNATIONAL RESIDENTIAL CODE ADOPTED AND 14-1B-2 INTERNATIONAL RESIDENTIAL CODE AMENDMENTS BY REPEALING SUCH SECTIONS AND ENACTING NEW SECTIONS IN LIEU THEREOF ADOPTING THE 2015 INTERNATIONAL RESIDENTIAL CODE NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF DUBUQUE, IOWA: Section 1. Section 14-1B-1 of the City of Dubuque Code of Ordinances is amended by repealing Section 14-1B-1 and enacting a new Section 14-1B-1 in lieu thereof as follows: 14-1B-1: INTERNATIONAL RESIDENTIAL CODE ADOPTED: Except as hereinafter added to, deleted, modified, or amended, there is hereby adopted by reference as the building code of the city that certain building code known as the international residential code, 2015 edition, and as published by the International Code Council, Inc., and the provisions of such building code shall be controlling in the construction, remodeling, maintenance, repair, and reconstruction of one- and two- family residential buildings and in all matters covered by such building code within the corporate limits of the city and shall be known as the "Dubuque residential building code". A copy of the international residential code, 2015 edition, as adopted, shall be on file in the office of the city clerk for public inspection. Section 2. Section 14-1B-2 of the City of Dubuque Code of Ordinances is amended by repealing Section 14-1B-2 and enacting the following additions, deletions, modifications, or amendments of the International Residential Code, 2015 Edition, adopted in Section 14-1B-1 to read as follows: The following additions, deletions, modifications, or amendments of the international residential code, 2015 edition, adopted in section 14-1B-1 of this article to read as follows: Section R102.7 Existing Structures. Amended to read: R102.7 Existing structures. The legal occupancy of any structure existing on the date of adoption of this code shall be permitted to continue without change, except as is specifically covered in this code, the International Property Maintenance Code as adopted by the City of Dubuque in Title 14, Chapter 1, or the International Fire Code as adopted by the City of Dubuque in Title 14, Chapter 1, or as is deemed necessary by the code official for the general safety and welfare of the occupants and the public. Section R103.1 Creation of Enforcement Agency. Amended to read: Sec. R103.1. Creation Of Enforcement Agency. There is hereby established in the city the building services department, which shall be under the jurisdiction of the code official. Section R105.5 Expiration. Amended to read: Sec. R105.5. Expiration. Every permit issued shall become invalid unless the work on the site authorized by such permit is completed within one year after its issuance. The code official is authorized to grant, in writing, one or more extensions of time, for periods not to exceed 180 days. The extensions shall be requested in writing and justifiable cause demonstrated. Section R112.1 through R112.4 replaced with City of Dubuque Code of Ordinances Section 14-1A-6. Section R113 Violations. Amended to read: Sec. R113. Violations. It shall be unlawful for any person, firm or corporation to erect, construct, enlarge, alter, repair, move, improve, remove, convert or demolish, equip, use, occupy or maintain any building or structure or cause or permit the same to be done in violation of this code. The doing of any act, or the omission of any act, declared to be unlawful by this code, or any code or ordinance herein adopted by reference shall be deemed a separate offense for each and every day or portion thereof during which any such unlawful act is committed, continued or permitted and upon conviction shall be punishable as provided in title 1 of the code of ordinances. The penalty herein provided shall be cumulative with and in addition to the revocation, cancellation or forfeiture of any license or permit elsewhere in this code provided for violation thereof. A notice of violation is not required in every situation and city staff may issue a municipal infraction without previously issuing a notice of violation. Section R202 Definitions. Amendment to "Building Official" and inclusion of "Code Official": BUILDING OFFICIAL. See "CODE OFFICIAL". CODE OFFICIAL. The officer or other designated authority charged with the administration and enforcement of this code, or a duly authorized representative. Any reference to "BUILDING OFFICIAL" in this code refers to "CODE OFFICIAL". Section R302.2.2 Parapets for Townhouses. Deleted. Section R302.2.3 Parapet Construction. Deleted. Section R303 Light, Ventilation and Heating. Deleted. Section 310.1 Emergency Escape and Rescue Opening Required. Amended to read: Sec. R310.1. Emergency Escape And Rescue Required. Basements, habitable attics, and every sleeping room shall have at least one (1) operable emergency escape and rescue opening. Where basements contain one or more sleeping rooms, emergency egress and rescue openings shall be required in each sleeping room. Where emergency escape and rescue openings are provided they shall have a sill height of not more than 44 inches (1118 mm) above the floor. Where a door opening having a threshold below the adjacent ground elevation serves as an emergency escape and rescue opening and is provided with a bulkhead enclosure, the bulkhead enclosure shall comply with section R310.3. The net clear opening dimensions required by this section shall be obtained by the normal operation of the emergency escape and rescue opening from the inside. Emergency escape and rescue openings with a finished sill height below the adjacent ground elevation shall be provided with a window well in accordance with section R310.2. Emergency escape and rescue openings shall open directly into a public way, or to a yard or court that opens to a public way. Exceptions: 1. Basements used only to house mechanical equipment and not exceeding total floor area of 200 square feet (18.58 m2). 2. Basements without bedrooms that provide a second stairway that terminates in a room separate from the first stairway. 3. The finished sill height may exceed 44 inches (1118 mm) above the floor if approved by the code official and the following conditions are met: a. The exterior finish grade is more than 36 inches (914 mm) above the interior floor level of the room, or altering the exterior configuration of the building would adversely affect the historical significance of the building. b. A platform capable of supporting a live load of 300 pounds shall be permanently affixed at the interior of the window. This platform shall be no lower than 20 inches (508 mm) above the floor and no higher than 36 inches (914 mm) above the floor. The distance from the platform to the finished sill height shall not exceed 36 inches (914 mm). The platform shall extend outward from the wall a minimum of 24 inches (610 mm) and shall be at least as wide as the clear openable width of the window. c. The escape or rescue window shall comply with section R310.2. d. The building is equipped with smoke detectors installed in accordance with section R31, Section 311.7.8.2 Continuity. Amended to read: Sec. R311/.8.2. Continuity. Handrails for stairways shall be continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inch (38 mm) between the wall and the handrails. Exceptions: 1. Handrails shall be permitted to be interrupted by a newel post at a turn. 2. The use of a volute, turnout or starting easing shall be allowed over the lowest tread. 3. Top rails may be interrupted by walls. Section 313 Automatic Fire Sprinkler Systems. Deleted. Section R404.1.2 Design of Masonry Foundation Walls. Amended to read: Sec. R404.1.2. Concrete Foundation Walls. Concrete foundation walls that support light -frame walls shall be designed and constructed in accordance with the provisions of this section, ACI 318, ACI 332 or PCA 100. Concrete foundation walls that support above -grade concrete walls that are within the applicability limits of section R611.2 shall be designed and constructed in accordance with the provisions of this section, ACI 318, ACI 332 or PCA 100. When ACI 318, ACI 332, PCA 100 or the provisions of this section are used to design concrete foundation walls, project drawings, typical details, and specifications are not required to bear the seal of the architect or engineer responsible for design, unless otherwise required by the state law of the jurisdiction having authority. Exception: The following reinforcement requirements may be used as an alternative for 8" (204 mm) thick concrete foundation walls between 96 (2438 mm) and 120 inches (3048 mm) in height: #4 bars 20 inches (508 mm) on center vertically and #4 bars 24 inches (610 mm) on center horizontally. Section 405.1 Concrete or Masonry Foundations. Amended to read: R405.1 Concrete or masonry foundations. Drains shall be provided around concrete or masonry foundations that retain earth and enclose habitable or usable spaces located below grade. Drainage tiles, gravel or crushed stone drains, perforated pipe or other approved systems or materials shall be installed at or below the area to be protected and shall discharge by gravity or mechanical means into an approved drainage system. Gravel or crushed stone drains shall extend not less than 1 foot (305 mm) beyond the outside edge of the footing and 6 inches (152 mm) above the top of the footing. The top of open joints of drain tiles shall be protected with strips of building paper. Except where otherwise recommended by the drain manufacturer, perforated drains shall be surrounded with an approved filter membrane or the filter membrane shall cover the washed gravel or crushed rock covering the drain. Drainage tiles or perforated pipe shall be placed on a minimum of 2 inches (51 mm) of washed gravel or crushed rock not Tess than one sieve size larger than the tile joint opening or perforation and covered with not less than 6 inches (152 mm) of the same material. Exception: A drainage system is not required where the foundation is installed on well -drained ground or sand -gravel mixture soils according to the Unified Soil Classification System, Group I soils, as detailed in Table R405.1. Section N1101.14 (R401.3) Certificate (Mandatory). Deleted. Section N1102.4.1.2 (8402.4.1.2) Testing. Deleted. Section N1103.3.4 (R403.3.4) Duct Leakage (Prescriptive). Deleted. Section N1103.3.5 (R403.3.5) Building Cavities (Mandatory). Amended to read: Section N1103.3.5 (R403.3.5) Building Cavities (Mandatory). Exterior building framing cavities shall not be used as ducts or plenums. Section 2903.6 Determining Water Supply Fixture Units. Amended to read: 9 Sec. P2,43.6. Freezing. As Dubuque requires a winter design temperature of 32 degrees Fahrenheit (0 degrees Celsius) or lower as shown in table R301.2(1) of this code, a water, soil or waste pipe shall not be installed outside of a building, in exterior walls, in attics or crawl spaces, or in any other place subjected to freezing temperature unless adequate provision is made to protect it from freezing by insulation or heat or both. Water service pipe shall be installed not less than 6 inches (152 mm) below the frost line. Section P2904 Dwelling Unit Fire Sprinkler Systems. Deleted. Chapter 30 Sanitary Drainage. Deleted. Section P3114.3 Where Permitted. Amended to read: Sec. P3114.3. Where Permitted. Individual vents, branch vents, circuit vents and stack vents shall be permitted to terminate with a connection to an air admittance valve when approved by the building official or their agent in cases where structural or existing conditions do not allow for the termination of a vent to the exterior of the structure. Individual and branch type air admittance valves shall vent only fixtures that are on the same floor level and connect to a horizontal branch drain. Part VIII "Electrical" is hereby amended by deleting chapters 34-43 in their entirety. Appendix A — Adopt Appendix B — Adopt Appendix C — Adopt Appendix D — Adopt Appendix E — Do Not Adopt Appendix F — Do Not Adopt Appendix G — Adopt Appendix H — Adopt Appendix I — Do Not Adopt Appendix J — Adopt Appendix K — Do Not Adopt Appendix L — Do Not Adopt Appendix M — Do Not Adopt Appendix N — Adopt Appendix 0 — Do Not Adopt Appendix P — Do Not Adopt Appendix Q — Do Not Adopt Appendix R — Do Not Adopt Appendix S — Do Not Adopt Appendix T — Do Not Adopt Appendix U — Do Not Adopt Section 3. This Ordinance takes effect July 1, 2016. Passed, approved, and adopted the 6th day of June, 2016. Ric r . Jones, ayor Pro -Tem Attest: • OFFICIAL ORDINANCE_NO 27 16. AMENDING CITY OF, DUBUQUE'CODE'0F ORDINANCES ;TITLE 14'BUILDING AND,DE- VELOPMEN.T, TER';'L BUILDING, CO. DES, ARTICIE'B REST= DENTIAL,�C.ODE, -SEC-- TIONS ;14484 INTER- NATIONAL RESIDEN- TIAL ,CODE ADOPTED AND 14-1B-2 INTER= NATIONAL;'''. RESIDEN- TIAL ','CODE.' AMEND- MENTS,'BY L- ,REPEA INC• SUCH`; SECTIONS AND ENAACTING "NEW SEC'TIO`t$S, IN' LIEU THEREOF,, ADOPTING THE 2015; INTERNA. TIONAL RESIDENTIAL CODE NOW, THEREFORE, RE. IT ORDAINED :BY by the City of Dubuque in Title; 14, Chapter 1, or as is deemed„ eces- sary-by ,the code offi- cial , for the general safety and welfareof the occupants and the public. Section R103.1 Crea- tion of Enforcement Agency.. Amended to read: Sec. R103.1. Creation Of Enforcement Agen- cy. There is hereby es- tablished in the city the building services de- partment, -which shall be under the jurisdic- tion of the code offi- cial. . Section 'R105.5 Expira- tion. Amended to read: Sec. -R105.5..'Expira- tion.. Every .permit is- sued shall become in- valid unless the work on the site authorized by.such. permit is com- pleted within oneyear after its issuance. The code official is author- ized to grant, in writ- ing, one or -more exten- sions of time, for peri- ods not to. exceed 180 days. The extensions shall,be ; requested in writing ?and justifiable cause :demonstrated. .Section R112.1 through; R112.4 • re- placed e placed with City•of Du- buqueaiCdde' of Ordi- nances Section 14-1A- 6. Section R113 SViola- tions. Amended c ,to read: Sec R113. Violations. It shall be Unlawful for any 'person, firm or corporation to erect, construct, enlarge, al- ter,, repair,move, im- prove; remove, convert or+ demolish, equip, use, :occupy, on; Blain, tain any- building or structure or cause, or permitahe same to be done in violation of this code.' The doing of any act, or, the omission of any act, declared to be un- lawful by this code, or any; code: or ordinance herein adopted by ref- erence shall be deem- ed a separates offense for .each and every day or portion thereof dur- ing which any such un,. lawful act, is commit- ted, ;continued or per- mitted_and :Upon .con- victiorrshall•be punish- able as provided in title 1 -of the, code of ordi- nances. ,The penalty herein, provided shall be cumulative with and in addition to the revo- cation .cancellation or forfeiture of any. li- cerise or, permit else- where in this; code pro- vided for violation thereof. •. - . A notice of•violation °is not required in ,every situation and city staff may issue a;municipal infraction "without pre= viously issuing a&notice of violation. , Section R202 ;Defini- tions. Amendment to "Building Official" and inclusion of 'Code.Offi- cial": ) BUILDING ;OFFICIAL. See 'CODE OFFICIAL . ,CODE•,OFFICIAL, The officer or other desig- nated authority:charg- ed.with the administra- tion and enforcement of this code, ora duly authorized representa- conditions are met: - Unified Soil' Classifica- .I a, The exterior. finish tion Systern, • Group 1 grade is more than 36 soils, as detailed in Ta- inches (914 mm)'above ble R4051. ; " the interiorfloor, level Section N1101.14 of the room, or altering (R401.3) Certificate the exterior. configura- (Mandatory). Deleted. tion of the building Section N1102.4.1.2 would adversely affect (R402.4.1.2) '`;Testing. the 'historical signifi-' Deleted cance of the_building: Section .N1103.3.4 b.•A platform capable (R403,3.4) Duct: Leak- of supporting a live age (Presc'riptive). De load of,` 300 pounds feted: shall -be permanently .Sectiohl N1103.3.5 affixed at the interior (R403.3.5) ,• " , !Building: of the twindow.'`This Cavities '(Mandatory). platform shall be' no Amended to read: lower, than -20 .inches : Section !N1103.3.5 (508 mm). above the (R403.1.5)-- Building floor end:i.no higher Cavities (Mandatory).; than' 86 inches .(914 Exterior building fram- mim above -"the .floor, Ing cavities shall not be The distance from the used as ducts or platform to the finish- plenums. `• edsill :height shall not Section`2903.6 Deter - exceed 36`inches (914. mining, Water Supply 'mm). The. platform Fixture Units. Amended shall .extend,outward to read: . from. the Wala mini- Sec ; P2603.6 Freez mum of 24 inches; (610 ing, As Dubuque, re mm) and :,shall be -at quires a winter. design least as wide as the temperature of;32 de= clear openable width grees`Fahrenheit (0 de - of the window. grees Celsius)'orlower c. The escape or. res- as shown:: in table I cue window shill con,- R301.2(1) of this code; ply with section R310.2. a water,'sofl-or waste d. The building:; is pipe shall not. be instal- equipped with smoke led`dutside.ofra build detectors, sinstalled jin ing, in exterior=walls, in accordance with sec- attics or crawl spaces, tion R31,3.:-. or in any .other -place section;31178.2 Con- subjected to :,freezing tinuity. Amended to temperature unless ad- read:...--- ;„ d -read . equate :,provision, ;is Seo. 831.7.8.2. Con- madeto protect it from tinuity. Handrails for freezing by. insulation stairways shall. be• con- or heat or•both. Water tinuous for ;the full service pipe shall be in length of . the flight, stalled not less, than !6 from =a point" directly inches (152 mm) below above the ,top riser of thefrostline: the flight to a' point di- Section P2904. Dwell- rectly above the lowest ing Unit-Fite'Spfmkler riser'. of the ' flight. Systems Deleted. ` ' Handrail ends shall be . Chapter 30._Sanitary returnedor.shall termi- Drainage Deleted. . nate lin newel. posts,` or -Section i 03114.3 safety terminals: Hand- Where :Perimtted; rails adjacent to.a wall Amended to•read shall have a space,. of Sec P3114:3.,,Where not less than 11/2 inch Permitted. Individual (38. mm) between ,the, vents branch' vents, wall and the handrails, circuit vents; and, stack Exceptions, Vents shall be permit 1. Handrails shall be tedto terrni.nate with a . permitted to. be inter- corinection to. 'an. aft rupted by, a newel post admittance valve where at a turn. approved by fhe build; • 2. The use of a volute, ing official' ,or, their turnout or starting eas- agent in` case's where ing shall be allowed structural or.existing over the lowest tread., conditions do not allow 3 Top rails May be in- for the ter01.44tl0n of a terrupted,;by walls. vent to the'exterfor;of Section;313 Automatic the structure;,`. Fire•Sprinkler Systems. Individual and'branch Deleted type air admittance Section'R404.1.2 De- valves shall vent only signG of;Masonry Foun- fixtures that "are on the I dation-Walls.;' Amended same floor ,level tp'read: , connect to a;horizontal !Sec. R4041.2. •Con - branch drain.: Crete' Foundation Walls. Part VIII 'Electrical", is Concrete• ,. foundation hereby'amended ':by _1 walls:: that . support deleting chapters 34=43.;1 light -frame walls shall in their entirety be, designed 'and con -'Appendix A=;,Adopt;',; structed in accordance Appendix B -Adopt with the- provisions of Appendix C. ';Adopt ,,, this , section, ACI 318, 'Appendix 120"-,.; AdoOt , 'ACI 332 or ,PCA' 100, Appendix E . Do Not. Concrete - foundation Adopt wails that - -support Appendix F Do, Not above -grade concrete Adopt " walls that,: are within -Appendix G' -Adopt the applicability limits Appendixes Adopt of section R611.2 shall Appendix I Do Not be;.designed'and con- Adopt strutted. it) accordance i Appendix -Adopt with "the:provisions,•of Appendix K;`- Do Not this sectionv ACI 318, "Adopt :ACI. 332.:or':PCA 100. Appendix L," --Do Not ,.,' When ACI -318, ACI ; Adopt; t PCA 100 or the ptovi- Appendix M' Do Not sions of this` section Adopt are used to design con- Appendix N' - Adopt crete foundation walls, Appendix 0 - Do Not project drawings, typi- Adopt cal details, and specifi- Appendix P`- Do Not SEOTIOHS' IN `LIEU fficer�or other` d oesig- THEREOF,; ADOPTING naicer.authority charg- s THE 2015 INTERNA- ed this. with codethe administra, TIONALCODE RESIDENTIAL " tion of and enforcement NOW, THEREFORE, authorized repor'resa entalduly- BE IT ORDAINED BY tive. Any reference to THE CITY COUNCIL "BUILDING OFFICIAL" OF THE CITY OF DU- in this code refers; to BUQUE, IOWA: "CODE OFFICIAL". Section 1. Section 14- Section R302.2.2 Para - 1B -1 of the City of Du- pets for Townhouses. buque Code of Ordi- Deleted. nances is amended by Section R302.2.3 Para - 1B -pealing Section 14- pet` Construction. De - 1 and enacting 'a leted new Section 14-1B-1 in Section R303 tight; lieu thereof as follows: Ventilation and Heat - 14 -16-1: INTERNA- ing. Deleted. TIONAL RESIDENTIAL .Section 310.1 Emer- CODE ADOPTED: gency Escape and Res Except as :hereinafter cue Opening Required. added to; ,• deleted, PCA 100 or'.the prow Appendix M - Do Not ions of this section Adopt are used to design con- Appendix N,- Adopt crete foundation walls, Appendix 0 - Do Not project drawings, typi- ,Adopt cal details, and.specifi- Appendix P - Do Not cations are not re- Adopt quired to bear the seal Appendix Q - Do Not of the architect or en- Adopt gineer responsible for Appendix:R - Do Not design, unless other- Adopt wise required, bythe Appendix S - Do Not state law of the juris- Adopt diction having authori- Appendix T - Do Not ty. , Adopt Exception: Appendix U - Do Not The following rein- Adopt. forcement require- Section 3: This Ordi.- ments fnay be used as nance takes effect July an alternative for 8'. 1, 2016. (204 mm) thick : con- Passed, approved, crete foundation walls and adopted: the, 6th between 96 (2438, mm) day of June, 2016. and 120 : inches (3048 /s/Ric W. Jones, Mayor mm) in height: #4 bars Pro -Tem 20 inches (508 mm) on "Attest:/s/Kevin S. center vertically and Firnstahl,,City Clerk #4 bars 24 inches (610 Published officially in mm) -on center horizon- the Telegraph' Herald'` tally. newspaper on the 24th Section 405.1 Con- day of June, 2016. • , crete or Masonry Foun- /s/Kevin S. Firnstahl, dations. Amended to City Clerk read: 116/24 R405.1 Conceete ,or masonry foundations: Drains shall be provid- ed around concrete or masonry foundations that retain 'earth` and,; enclose habitable, or usable spaces located below'grade. Drainage tiles, gravel or crushed stone drains, perforat- ed pipeor other ap- proved systems or:ma- teriais shall be instal- led /at or below the areatlto be protected and shall discharge by gravityor mechanical means ' into an ap- proved drainage sys- tem. Gravel or crushed stone drains shall ex- tend not less than 1 foot (305 mm) beyond the outside edge: of the .' footing and • 6 inches (152 mm) above 'the top of the footing. The topof open joints of drain tiles shall be.pro tected. with strips of building paper. Except where otherwise rec- ommended, by • the drain ; manufacturer, perforated drains shall be surrounded with an approved filter' mem- brane or the : filter membrane shall cover the washedgravel or crushed rock covering the ::drain." Drainage tiles or perforatedpipe shall be placed—on a minimum :of 2 inches (51 mm) of . washed gravel or crushedrock not less than one sieve size larger than the tile joint opening or'perfo- ration and covered '. with notless than 6 in- ches (152 n-ches"(152 mm) of the same material. Exception: A drainage system is not required where the foundation is installed on well drained ground or sand -gravel mixture soils according;. to the Amended to read: modified, or amended, sec. :R310.1..;Emerges there is hereby adopt- .. cy Escape And Rescue ed by reference as thRequired. = Basements,' building code of the habitable . attics, and city that certain build- every sleeping room ing code known as the shall have at least one international reiden(1) operable emergen- tial code, 2015 edition, cy eseaperand rescue and as "published; by opening. Where base - the International Code ments containone or Council, Inc.; and the more sleeping rooms, provisions of such emergency -egress and controlling osun l code shall be rescue' openings shall controlljng'in the con be required in each struction, remodeling, sleeping room. Where maintenance repair, emergency escape and and reconstruction of rescue openings are one- and two-family provided they shall residentialbuildings have a sill, height of not and in`all matters ding more than 44 inches ered by such building' (1118(mm)above the code within the corpo' floor. Where a " door rate limits of the city opening having a and shall be known as threshold ,below:. the the "Dubuque residen- tial building code A tiof serves as an emer copy of the interna- gency escapeand res- ional residential code, cue opening and is pro 2015 edition, as adopt- vided with a bulkhead ed, shall be on file in enclosure, the bulk - the office of the city head enclosure shall clerk for public inspec- comply with section ;net clear opening 8310.3. The dimensions re- quired by this section. shall be obtained by, the normal operation of the emergency es- cape- and rescue open ing': from the inside. Section 2. Section 14- 16-2 of the City of'Du- buque .Code of Ordi- nances is amended by repealing Section 14- 16-2 and enacting the following additions, de- letions, )modifications, Emergency escape and or'amendmentsTonalof the" rescue. openings with a International Resides- finished sill height be tialo, 2015 Edition; low the adjacent adopted in Section 14- ground elevation shall 1B-1 to read as follows:. be provided with a win - The following addi- tions,dow well accordance ' deletions, modify with section . R310.2. cations, or amend- Emergency escape andt. ments of• en al code,a- rescue openings shall 2i 15 residential open directly into a in 'sections edition, adopted - public way, or to. a yard i thisarticleto14read asof r court that opens to a to read as follows: Public way. ;1 Section R102.7 Exist- ' Exceptions ing Structures. Amend- 1. Basements` used ed to read: only to House mechani; cal equipment and hot 8eExisting struc-occu- exceeding total floor tures. Theflegal uarea of 200 square feet pancy of onat structuredteof (18.58 m2). existiadoptionng thedate 2 Basements without shalle of'm t - code bedrooms that provide continueinue` permitted ut a second stairway that nwithout terminates in a ; room change, except ed is separate from the first tthis code,,y the Interna -ed in stairway., Pror3. The finished sill nancel Code adoptedte- height may,: exceed' 44 nance-Code as adopted by the City of Dubuque inches (1118 mm) in Title' 14, Chapter 1, above the floor if ap- or the. International proved by the code of- Fire Code as adopted ficial and the following